www.skcltd.comFlite 2 High Volume Air Sampling PumpOperating InstructionsThis manual covers the following models:901-2011 & 901-2012
Page 8 901-FTM Issue I www.skcltd.comGetting Started3) Use of the Keypad and LCD ScreenKey functions - - Switches between menu options and selects d
www.skcltd.com 901-FTM Issue I Page 9Getting StartedOn number entry menu screens such as the sample run time screen, each digit of the hours and min
Page 10 901-FTM Issue I www.skcltd.comProgramming the Flite 2 Pump1) Waking the Pump from Sleep ModeWhen not in use the pump should be put into ‘Sle
www.skcltd.com 901-FTM Issue I Page 11Programming the Flite 2 PumpSelect the ‘YES’ option in the ‘SET UP NOW ?’ menu screen, and press to display
Page 12 901-FTM Issue I www.skcltd.comProgramming the Flite 2 PumpHaving set the required pump flow rate disconnect the flow calibrator from the sam
www.skcltd.com 901-FTM Issue I Page 13Programming the Flite 2 PumpTo enter a sample run time select the ‘YES’ option, and press to display the next
Page 14 901-FTM Issue I www.skcltd.comProgramming the Flite 2 PumpPress to save the start delay time and display the next menu screen. Æ REPEAT RU
www.skcltd.com 901-FTM Issue I Page 15Programming the Flite 2 PumpTo check the pump flow rate select the ‘YES’ menu option and press . The pump wil
Page 16 901-FTM Issue I www.skcltd.comProgramming the Flite 2 PumpIf the sample is to be carried out at a later time, put the pump into Sleep mode b
www.skcltd.com 901-FTM Issue I Page 17Operating the Flite 2 Pump1) Manual RunHaving programmed the desired flow rate and fitted a new filter into th
Page 2 901-FTM Issue I www.skcltd.comPurchase Details and Service HistoryThank you for choosing an SKC product. Your purchase is covered by our warr
Page 18 901-FTM Issue I www.skcltd.comOperating the Flite 2 PumpTo stop the pump at the end of the required sample period, press the and select ke
www.skcltd.com 901-FTM Issue I Page 19Operating the Flite 2 Pump3) Timed Run with Delayed StartHaving previously programmed a timed run with delayed
Page 20 901-FTM Issue I www.skcltd.comOperating the Flite 2 PumpAt the end of the first start delay time the pump will automatically start and the ‘
www.skcltd.com 901-FTM Issue I Page 21Operating the Flite 2 PumpTo restart the pump from Hold, press the keys in the sequence , , . The pump will
Page 22 901-FTM Issue I www.skcltd.comTroubleshootingShould the Flite 2 pump detect that the battery is at a low charge state a low battery message
www.skcltd.com 901-FTM Issue I Page 23Battery CareThe Flite 2 pump utilises sealed, valve regulated, lead/acid batteries. This type of battery requi
Page 24 901-FTM Issue I www.skcltd.comFlite 2 Pump ComponentsCasing foot1Casing screw2Casing screw2Casing lidBattery3Battery clamping bracket, nuts
www.skcltd.com 901-FTM Issue I Page 25Flite 2 Pump Head and Motor ComponentsPump head inlet/outlet tubeO ringValve housingValve diaphragmValve retai
Page 26 901-FTM Issue I www.skcltd.comFlite 2 Pump Replacement PartsItem Part No. Description Item Part No. Description1 P901111 Casing feet (pack o
www.skcltd.com 901-FTM Issue I Page 27Flite 2 Pump AccessoriesPart No. Description901-210 Battery charger 100-240V ~ 50/60Hz - 12Vdc 1A with UK/EU/U
www.skcltd.com 901-FTM Issue I Page 1ContentsSpecifications ...
Page 28 901-FTM Issue I www.skcltd.comWarranty InformationLimited One Year Warranty1. SKC warrants that this instrument, and each of its component p
www.skcltd.com 901-FTM Issue I Page 29Warranty Informationto the buyer. The remedy will consist of service or replacement of the instrument, or ref
A member of the SKC global group of companiesSKC Limited 11 Sunrise Park, Higher Shaftesbury Road, Blandford Forum, Dorset DT11 8ST United KingdomT: +
Page 2 901-FTM Issue I www.skcltd.comSpecificationsDimensions ...178mm W x 115mm H x 206mm DWeight
www.skcltd.com 901-FTM Issue I Page 3SpecificationsPump FeaturesBattery capacity optionsChoose from two capacities of internal battery - 3.2Ah (Part
Page 4 901-FTM Issue I www.skcltd.comSpecificationsTypical Pump Run TimesFilter Type Flow RateRun Time P9012013.2Ah BatteryRun Time P9012027Ah Batte
www.skcltd.com 901-FTM Issue I Page 5General Information1) Pump Models901-2011 Standard single port pump901-2012 Twin port pump for through flow app
Page 6 901-FTM Issue I www.skcltd.comThe Flite 2 PumpInlet hosetail LCD screen Charging /power socketKeypadCarry handle Screw-in cap Casing feetCasi
www.skcltd.com 901-FTM Issue I Page 7Getting Started1) Fitting the BatteryThe Flite 2 pump is supplied without a battery. Refer to the instructions